How much energy will your solar system produce?
Start from your system capacity, location, panel direction and tilt. This tool runs a climate-adjusted simulation at your coordinates - one reference year of hourly solar and temperature data corrected toward five years of historical weather statistics - then returns an expected annual generation (P50), a P90 planning estimate, a monthly production profile and a breakdown of the factors modeled. Every figure is an estimate - a planning figure, not a guarantee.
Your system & location
Tell us the size of the system you are planning (or already have) and where it will be installed. Location feeds the historical weather data.
System Capacity (kWp)
e.g. 10 kWp for a typical home/roof
Location
Search a city, use your browser GPS, or enter latitude/longitude manually.
Panel direction & tilt
Where your panels face and how steeply they are angled has a big effect on yearly output.
Panel Direction
Advanced: exact azimuth (0° = North, 180° = South)
Tilt Angle
Auto picks the recommended angle for your latitude. Your chosen angle is shown in the results.
Soiling Assumption
Advanced: exact annual soiling %
Engineering settings (optional)
Advanced inputs are pre-filled with sensible defaults. Change them only if you know your actual panel and installation values.
Typical System Losses (%)
Cables, inverter, mismatch, availability - typical 8%
Temp Coefficient (%/°C)
NOCT (°C)
Panel operating temperature
Traffic Limit: please wait about 60 seconds after every 3 simulations to let the weather data service cool down. If the simulation stalls, refresh the page.
Climate Audit
Enter your system details and location, then run the analysis to fetch historical weather data and compute an expected annual generation (P50) and a P90 planning estimate.
Fetching weather dataset...
Estimated Annual Generation
≈ -- kWh per month on average
Expected Annual Generation (P50)
P90 Planning Estimate
A planning estimate from historical variability and modeled uncertainty. Not a lender-certified P90 assessment.
Specific Yield
What does this mean?
--
Annual Performance Metrics
Modeled PR
-- % PRModeled from simulated energy & irradiance. Not a measured plant PR.
Capacity Factor
-- %Average Daily
-- kWhAverage Monthly
-- kWhPlane-of-Array (POA)
-- kWh/m²/yrPeak : Min Month
-- ratioEnvironmental Effects (annual average)
Fixed System Loss
-- %Cables, inverter, mismatch
Temperature Effect
-- %Estimated hourly module temperature. Positive = gain when cooler than 25°C; negative = loss when hotter.
Soiling Assumption
-- %Your dust/rain assumption, not measured accumulation
Combined Modeled Loss
-- %Multiplicative combination of the factors above
The fixed and soiling factors reduce the energy that reaches the grid compared with ideal PV output; the temperature effect is a small gain in cool climates and a loss in hot ones. All three are combined multiplicatively.
Simulation Location
Unknown
-- , --
Inter-annual Variability (σ)
--%
Avg Annual Insolation
-- kWh/m²
Recommended Tilt
--°
Monthly Generation Profile
Annual Yield Confidence
Annual P50 vs P90 planning estimate. Monthly P90 figures are not statistically meaningful, so they are not charted.
Irradiance vs Generation
Monthly Physics Breakdown
| Month | POA (kWh/m²) | Avg Temp (°C) | Temp Effect | Soiling | Total Energy (kWh) | Avg/day (kWh) | CUF % |
|---|
Assumptions & Data Quality
Advanced methodology
Model: 5-year GHI statistics (current year minus 5 through previous year) + 1-year hourly tilted simulation + monthly climate correction.
Simulation: hourly Plane-of-Array (POA) irradiance from the Open-Meteo archive for the reference year, scaled to the long-term monthly average. Module temperature is estimated hour-by-hour as ambient + (POA/800) × (NOCT − 20). Actual module temperature depends on wind, mounting configuration and module construction, so this is a simplified planning model.
Factors: fixed system losses (your aggregate input), your soiling assumption and an estimated temperature multiplier (1 + coefficient/100 × (Tcell − 25), where a cell cooler than 25°C produces a gain), combined multiplicatively into hourly energy.
P90: a planning estimate derived with a one-sided normal approximation using the inter-annual variability of annual GHI plus a 5% system uncertainty, combined by root-sum-square and applied at 1.282 sigma.
Limitations: P90 is a statistical planning figure, not a lender-certified P90 assessment. The model does not simulate module failure, inverter outage or shading, and uses a single reference-year hourly profile. Five to six annual weather observations is a small sample for a financial-grade estimate.
Next Steps
Frequently Asked Questions
Common questions about solar yield, P50/P90 estimates, losses and the data behind the simulation.
What is a P50 expected annual generation in solar?
P50 is the expected (median) annual production: in a typical weather year your solar system should produce around this amount. It is simulated from one reference year's hourly weather profile adjusted toward the five-year historical monthly average, a climate-adjusted reference-year simulation.
What is a P90 solar estimate, and why is it lower than P50?
P90 is a conservative planning figure you can expect to be reached or exceeded in about 9 out of 10 weather years. It is derived from the inter-annual variability of solar radiation plus a system uncertainty (for example 5%), combined by root-sum-square and applied at 1.282 standard deviations. It is a statistical planning figure, not a lender-certified bankability assessment.
How much energy will a 10 kWp solar system produce in a year?
Multiply the installed capacity by the location's specific yield. A typical 10 kWp equator-facing system in most of Pakistan produces about 13,000 to 17,000 kWh per year (a specific yield of about 1,300 to 1,700 kWh per kWp per year, higher in the tropics and the south). The simulation returns the exact figure for your location, direction and tilt.
How does panel direction and tilt affect solar output?
Face panels toward the equator for maximum annual output: south in the northern hemisphere and north in the southern hemisphere. A tilt close to your latitude is usually best, and the calculator recommends the angle automatically. East- or west-facing panels produce less annual energy but shift more generation into the morning or evening.
What are the typical losses for a solar system?
Typical system losses cover cables, inverter conversion, mismatch and availability, about 8% for a modern, well-built system (for example DC wiring 1.5%, AC wiring 1.0%, inverter 2.0%, mismatch 1.5%, availability 1.0%, other 1.0%). On top of that, the simulation adds an estimated temperature effect and your soiling assumption, all combined multiplicatively.
What is soiling loss and why does dust matter for solar?
Soiling is the average annual production lost to dust, bird droppings or snow cover. The calculator defaults to moderate (2%), which suits most sites; in dry, dusty climates choose a high soiling level or enter an exact percentage. Washing the panels periodically reduces this loss.
What do NOCT and the temperature coefficient mean?
The temperature coefficient (Pmax) is the percentage of power a panel loses for every degree Celsius above 25 degrees, for example -0.35%/C means 0.35% loss per degree. NOCT is the Nominal Operating Cell Temperature, the module's operating temperature under standard conditions, typically about 42 to 45 degrees C for modern panels. The simulation estimates module temperature hour by hour as ambient plus (POA/800) x (NOCT - 20).
What is the specific yield of a solar system (kWh/kWp)?
Specific yield tells you how many kWh each 1 kWp of installed capacity produces per year at a location, for example 1,400 kWh/kWp. Multiplying it by the installed capacity gives the annual generation, which is why the same panels can perform differently in different cities.
How accurate is this solar yield estimate and what weather data does it use?
This is a planning-grade estimate, not a guarantee. It uses five years of historical solar radiation and temperature data from Open-Meteo, runs one reference-year hourly tilted simulation, then corrects the result to the long-term monthly average. Five to six annual weather observations is a small sample for a financial-grade estimate, and the model does not simulate module failure, inverter outage or shading.
Will my solar system generate the same amount every year?
No. Weather varies from year to year, and the inter-annual variability of the location matters. The result shows a confidence note based on the coefficient of variation: low variability below 8%, moderate from 8% to 15%, and high above 15%. This year-to-year variation is exactly why both the P50 and the P90 planning estimate are displayed.
Next: is the design legal, and is it worth it?
You have verified production figures. These are the next three questions that use them.
Electrical design
String Sizing
Series-parallel layout and MPPT voltage windows, once you have picked a real inverter.
OpenFitting on the roof
Roof Space Checker
Whether the panel count behind those figures actually fits the roof you have.
OpenMoney math
ROI & Payback Analysis
Turn verified production into payback years and lifetime profit at your tariff.
OpenEverything in one page
Open the Complete Setup Calculator
Analyze every aspect of your solar project, sizing, roof space, battery, yield, string design and ROI, in one place, and generate a downloadable report of your results.
Open Complete Setup CalculatorLooking for a different tool? See the full calculator map — every tool, and the question each one answers — or browse the Learning Center.